High-precision Infrared Laser Contact Tachometer Measuring Instrument manual
0.1m/min (meter/minute) (above 100m/min)
0.1ft/min (inch/min) (0.1-999.99ft/min) 1ft/min(inch/min) (above 1000ft/min)
Intelligent Digital Tachometer User Manual
- Features1.
Beautiful appearance, easy to use and comfortable.
- Widemeasuringrange and high resolution.
- Using single chip microcomputer technology, photoelectric technology,anti-interference technology, can accurately Measure the speed value.
- Extralarge LCD display, clear readings.
- Automaticallymemorize themaximum value, minimum value and the last displayed value.
- Whenthebattery voltage is lower than the specified value, there will be a low battery symbol indication.
- Automaticallyshutdown. If no key is pressed, the power will automatically shut down after about 15 minutes.
Automatically shut down left and right.
- Specifications
VICTOR 6234P VICTOR 6235P VICTOR 6236P ÿ
ÿ ÿ ÿ
Note: Each model adopts the following technical indicators and operating methods according to the functions in the table.
monitor: 5-digit 16mm LCD display
Accuracy: ±ÿ0.05%+5ÿ
Range selection: Auto range
Effective distance: 50mmÿ500mm
size:
9V 6F22 Battery
Power consumption: less than 40mA
weight: About 200g (including battery)
Measuring range: 10ÿ99999 rpm (revolutions/minute) photoelectric speed method 1. 0ÿ19999 rpm (revolutions/minute) contact speed mode
1.00ÿ1999.9 m/min (meter/minute) contact line speed mode 3. 3ÿ6560 ft/min (inch/min) contact line speed mode
Resolution:
Photoelectric speed method: 0.1rpm (rev/min) (2.5ÿ999.99rpm) 1rpm(rev/min)(above 1000rpm)
Contact speed mode: 0.1rpm (rev/min) (0.5ÿ999.99rpm) 1rpm (rev/min) (above 1000rpm)
Contact line speed mode: 0.01m/min (meter/minute) (0.05-99.999m/min)
- OperationInstructions
- Poweron
.Install a 9V 6F22 battery and long press the ON/OFF button to turn the device on or off. Press this key to select function (VICTOR 6234P has no functionselection)
- Photoelectricspeed mode: (VICTOR 6234P and VICTOR 6236P have This feature)
A: Attach a reflective marker to the object to be tested.
B: Long press ON/OFF to turn on the device, short press ON/OFF to select the measurement mode photo RPM, If contact accessories are already installed, remove them.
(Note: dual-purpose tachometer) Note: VICTOR 6234P does not have function selection function. After powering on, the photo RPM measurement mode is displayed.
- Press the TESTkey to make the visible light beam and the target to be measured form a straight line.
After the displayed value stabilizes, release the test key TEST, but the maximum and minimum values of the measurement and the last displayed value are automatically stored in the instrument.
- Press theMEM key to display the maximum value, minimum value and last measured value.
Quantity value.
- Contactspeedmode
- Shortpress ON/OFF to select themeasurement mode contact RPM and install the contact accessories.
- Place the contactrubber head close to the object being measured and rotate it synchronously with the object being measured.
- Press the TESTkey to start measuring. After the displayed value stabilizes, release the test key.
Press the TEST key and the measured value will be automatically stored.
- Press theMEM key to display the maximum value, minimum value and last measured value.
Quantity value.
- Contactline speedmethod
- Press ON/OFF to select measurement modem/min (metric) or ft/min (imperial). Install the contact accessories.
- Place the contact fitting close to the objectbeing measured and rotate it synchronously with the object being measured.
- Press the TESTkey to start measuring. After the displayed value stabilizes, release the test key.
Press the TEST key and the measured value will be automatically stored.
- Press theMEM key to display the maximum value, minimum value and last measured value.
Quantity value.
- Measurement considerations
A: Reflective Marking: Cut a 12mm square of adhesive tape and stick it on each rotating axis.
It should be noted that the non-reflective area must be larger than the reflective area; if the axis is If it is shiny, you must first apply black paint or black tape, and then stick a reflective marker on it. Note: Before attaching the reflective marker, the shaft surface must be clean and smooth.
B: Low speed measurement, in order to improve the measurement accuracy, when measuring very low speed, It is recommended that the user evenly stick several reflective markers on the object to be measured.
Machine Translated by Google
The actual measured speed can be obtained by dividing the reading on the indicator by the number of reflective marks.
value.
- If theinstrument is not used for a long time, please remove the battery to prevent battery Damage to the instrument due to corrosion.
- Memory function description (MEM)
When the test key (TEST) is released, the display shows "0" and the current test value. The maximum, minimum and last measured value are automatically
Stored in the instrument. At this time, press the memory key (MEM) and the measured value will be displayed.
"MAX" represents the maximum value, "MIN" represents the minimum value, and "LA" represents the maximum value.
Each time you press the memory key, another memory value is displayed.
- Replace thebattery
- When thebatteryis lower than 7V, the LCD display will show
Symbol, the battery needs to be replaced.
- Open thebattery cover andremove the battery. Install the battery correctly.
Shenzhen Yishengshengli Technology Co., Ltd.
Address: 16th Floor, Block D, Tairan Building, Tairan 6th Road, Chegongmiao, Futian District, Shenzhen
Tel: 4000 900 306
ÿ0755ÿ82425035 82425036 Fax: (0755) 82268753
Email:victor@china-victor.com
Instrument accessories:
Reflective tape (photoelectric, dual-purpose tachometer) Length 600mm manual 1 Serving Contact line speed measurement accessories (contact, dual-purpose tachometer) 1 piece Contact speed measurement accessories (contact, dual-purpose tachometer) 3 pieces
The panel description is as follows
Contact wire speed accessories
Photoelectric
contact dual-purpose
accessories
Contact speed accessories
Power switch and function selection
Memory function keys
Note: For safety reasons, it is recommended to use Photoelectric measurement.